Renesas Electronics /R7FA2A1AB /CTSU /CTSUCR1

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CTSUCR1

7 43 0 0 00 0 0 0 0 0 0 0 0 (0)CTSUPON 0 (0)CTSUCSW 0 (0)CTSUATUNE0 0 (0)CTSUATUNE1 0 (00)CTSUCLK 0 (00)CTSUMD

CTSUCLK=00, CTSUATUNE1=0, CTSUMD=00, CTSUCSW=0, CTSUPON=0, CTSUATUNE0=0

Description

CTSU Control Register 1

Fields

CTSUPON

CTSU Power Supply Enable

0 (0): Powered off the CTSU

1 (1): Powered on the CTSU

CTSUCSW

CTSU LPF Capacitance Charging Control

0 (0): Turned off capacitance switch

1 (1): Turned on capacitance switch

CTSUATUNE0

CTSU Power Supply Operating Mode Setting

0 (0): Normal operating mode

1 (1): Low-voltage operating mode

CTSUATUNE1

CTSU Power Supply Capacity Adjustment

0 (0): Normal output

1 (1): High-current output

CTSUCLK

CTSU Operating Clock Select

0 (00): PCLK

1 (01): PCLK/2 (PCLK divided by 2)

2 (10): PCLK/2 (PCLK divided by 4)

3 (11): Setting prohibited

CTSUMD

CTSU Measurement Mode Select

0 (00): Self-capacitance single scan mode

1 (01): Self-capacitance multi-scan mode

2 (10): Setting prohibited

3 (11): Mutual capacitance full scan mode

Links

()